What was found
FRAME 258.5 FLANGE IS CORRODED STRINGER 31P-32P. REMOVED NECESSARY RIVETS AND REMOVED CORROSION IAW SRM 53-00-00-02-09. MIN THICKNESS NOTED .044", CONFIRMED CRACK FREE REF NTM REF NTM 51-00-04-910-801 PT 1, AND 51-00-06-910-801 PT 1. NOMINAL THICKNESS .040" NO MATERIAL LOSS AND FOUND TO BE IN LIMITS IAW SRM 53-00-00-02-09 AND SRM 53-30-15-00-01. ALODINED AND PRIMED AREA INSTALLED RIVETS SRM 51-42-05-02-01. APPLIED TOP COAT AND CPC IAW SRM 51-25-05-02-01 AND AMM 51-25-01-390-801.