What was found
FRAME 301 FLANGE IS CORRODED STRINGER 31S-33. REMOVED NECESSARY RIVETS AND BLENDED OUT CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. NOMINAL THICKNESS .040" AND NO REPAIR ALLOWED IAW SRM 53-30-15-00-01. HFEC INSPECTED, NO CRACKS DETECTED, MIN REMAINING THICKNESS .048" REF NDTM 51-00-04-910-801 PT 1, AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-2344 AND DWG 85361313. ALODINED AND PRIMED IAW SRM 51-21-10-02-01, 51-25-10-02-01. INSTALLED RIVETS IAW SRM 51-42-05-02-01. PAINTED AND APPLIED CPC IAW RD 8/4-53-2344.