What was found
FRAME 401 FLANGE IS CORRODED STRINGER 31S-32S. REMOVED NECESSARY RIVETS AND BLENDED OUT CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. NOTE NOMINAL THICKNESS .063" AND NO REPAIRS ALLOWED IAW SRM 53-30-15-00-01. MIN REMAINING THICKNESS .063" CONFIRMED CRACK FREE, REF NDTM 51-00-04-910-801, PT 1, AND 51-00-06-910-801 PT 1. NO MATERIAL LOSS AND FOUND IN LIMITS IAW SRM 53-00-00-02-09. ALODINED AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED RIVETS IAW SRM 51-42-05-02-01. PAINTED AND APPLIED CPC IAW SRM 51-25-05-02-01 AND AMM 51-25-01-390-801.