What was found
AFT WING SPAR FLANGE FOR PANELS 262HT, 262FT, AND 262AT HAVE AREAS OF BARE METAL AND FRETTING CORROSION. REMOVED FRETTING, MIN THICKNESS .092" AND FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-451. CONFIRMED CRACK FREE REF NDTM 51-00-06-910-801 PT 1. ALODINED AND APPLIED PRIMER IAW SRM 51-21-10-02-01 AND 51-25-10-02-01.