What was found
AFT SERVICE DOOR FWD FRAME HAS CORROSION AROUND 5 FASTENER HOLES FOR LINER. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .050", CONFIRMED CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MAPPED DAMAGE AND SUBMITTED TO ENGINEERING. MATERIAL LOSS IS FOUND TO BE WITHIN LIMITS IAW RD 8/4-52-898. APPLIED ALODINE AND PRIMER IAW RD 8/4-52-898. COMPLIED WITH TC 8/4-52-898.