What was found
CORROSION ON MATING SURFACE OF FRAME 49.5 AND STANCHION, STR 31S. STANCHION FOUND TO BE OUT OF LIMITS IAW SRM 53-20-43-00-01, NO DAMAGE ALLOWED. MATCH DRILLED NEW STATION IAW SRM 51-42-05-02-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON MATING SURFACE OF FRAME 49.5 AND STANCHION, STR 31S. STANCHION FOUND TO BE OUT OF LIMITS IAW SRM 53-20-43-00-01, NO DAMAGE ALLOWED. MATCH DRILLED NEW STATION IAW SRM 51-42-05-02-01.