What was found
FRAME 71.2 FLANGE IS CORRODED, STRINGER 32P-31P. REMOVED NECESSARY RIVETS AND REMOVED CORROSION IAW RD 8/4-53-2344 AND SRM 51-42-05-02-01, MIN REMAINING THICKNESS .042", CONFIRMED CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801 PT 1. INSTALLED RIVETS IAW SRM 51-42-05-02-01. ALODINED, PRIMED AND PAINTED IAW SRM 51-21-10-02-01, 51-15-10-02-01 AND 51-25-15-02-01. APPLIED CPC IAW AMM 51-25-01-390-801. FRAME FOUND IN LIMITS IAW RD 8/4-53-5166. COMPLIED WITH HORIZ TC RD 8/4-53-5166.