What was found
FRAME BS 116 FLANGES ARE CORRODED STR 33-29S. REMOVED FASTENERS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW RD8/4-53-2344. MIN REMAINING THICKNESS NOTED .022" CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801 PT 1. NOMINAL THICKNESS .040" IAW DWG 85328117. FRAME DAMAGE FOUND IN LIMITS IAW RD 8/4-53-5101. ALODINED AND PRIMED FLANGES IAW RD 8/4-53-5101. INSTALLED RIVETS IAW RD 8/4-53-5101. APPLIED PRIMER, PAINT AND CPC IAW RD 8/4-53-5105. COMPLIED WITH TC RD 8/4-53-5101.