What was found
LT NR 4 FLAP TRACK GOUGED ON INBD AND OTBD SIDES. BLENDED TRACK IAW SRM 57-50-50-02-01. PERFORMED ULTRASONIC THICKNESS TEST IAW SRM 57-50-50. ALL WITHIN LIMITS. EDDY CURRENT FOUND NO DEFECTS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT NR 4 FLAP TRACK GOUGED ON INBD AND OTBD SIDES. BLENDED TRACK IAW SRM 57-50-50-02-01. PERFORMED ULTRASONIC THICKNESS TEST IAW SRM 57-50-50. ALL WITHIN LIMITS. EDDY CURRENT FOUND NO DEFECTS.