What was found
FRAME 94.8 FLANGES AND WEB ARE CORRODED STR 33-29P. REMOVED FASTENERS COMMON TO SKIN AND STANCHION FOM BLENDED CORROSION IAW RD 8/4-53-2344, SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN THICKNESS NOTED .035" REF NDTM 51-00-04-910-801 PT 1, VERIFIED AFFECTED AREAS TO BE CRACK FREE REF NDTM 51-00-06-910-801 PT 1. FOUND BLENDS TO BE IN LIMITS IAW RD 8/4-53-5104. ALODINED, PRIMED, INSTALLED RIVETS APPLIED PRIMER AND TOP COAT IAW RD 8/4-53-5104. APPLIED EXTERIOR PRIMER AND TOP COAT IAW SRM 51-25-10-02-01 AND 51-25-15-02-01. COMPLIED WITH TC 8/4-53-5104.