What was found
STRINGER 30S IS CORRODED STA X 32.4 TO X 71.2. REMOVED RIVETS TO FOM IAW SRM 51-42-05-02-01. CLEANED STRINGER, CORROSION LIMITED TO FASTENERS ONLY IAW SRM 51-26-00-02-01. RESTORED SURFACE PROTECTION TO STRINGER IAW SRM 51-25-10-02-01 AND 51-25-15-02-01. INSTALLED RIVETS SRM 51-42-05-02-01. APPLIED PRIMER AND TOP COAT TO RIVETS IAW SRM 51-25-10-02-01 AND 51-25-15-02-01. APPLIED EXTERIOR TOP COAT TO OUTER SKIN IAW SRM 51-25-15-02-01.