What was found
FRAME 94.8, FLANGES AND WEB ARE CORRODED STR 33-31S. REMOVED FASTENERS COMMON TO SKIN FOM, BLENDED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. MIN THICKNESS NOTED .036" REF NDTM 51-00-04-910-801 PT 1. VERIFIED AFFECTED AREA CRACK FREE REF NDTM 51-00-06-910-801 PT 1. BLENDS FOUND TO BE WITHIN LIMITS RD 8/4-53-5104. ALODINED, PRIMED AND INSTALLED RIVETS RD 8/4-53-5104. APPLIED PRIMER, TOP COAT AND CPC RD 8/4-53-5104. APPLIED EXTERIOR PRIMER AND TOP COAT IAW SRM 51-25-10-02-01 AND 51-25-15-02-01. COMPLIED WITH TC RD 8/4-53-5104.