What was found
X547 FRAME FLANGES HAVE CORROSION BETWEEN STRINGERS 32P AND 31S. REMOVED RIVETS FOM IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02 MIN THICKNESS NOTED .045, CONFIRMED CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801, PT 1. MATERIAL LOSS FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-2344 AND DWG 85361328. CUT OFF DAMAGED FLANGE IAW RD 8/4-53-017. INSPECTED CUT LINE, NO DEFECT NOTED REF NTM 51-00-06-910-801 PT 1. FABRICATED REPAIR ANGLE IAW RD 8/4-53-2344. APPLIED ALODINE AND PRIMER TO REPAIR IAW RD 8/4-53-2344. INSTALLED REPAIR ANGLE, ALODINED, PRIMED AND INSTALLED RIVETS AT FRAME IAW RD 8/4-53-2344, SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. PAINTED IAW SRM 51-25-15-02-01.