What was found
INTERNAL SKIN HAS CORROSION STA X 49.5 TO X 71.2 BETWEEN STR 31P AND 32P. REMOVED RIVETS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. PERFORMED THICKNESS GRID OF BLENDED AREA MIN REMAINING THICKNESS NOTED .046". HFEC INSPECTED BLENDED AREA REF NDTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT1. BLENDS FOUND IN LIMITS IAW RD 8/4-53-5118. ALODINED, PRIMED AND INSTALLED RIVETS IAW RD 8/4-53-5118. APPLIED TOP COAT IAW RD 8/4-53-5118. APPLIED EXTERNAL TOP COAT IAW SRM 51-25-15-02-01. COMPLIED WITH TC RD 8/4-53-5118.