What was found
X216 FRAME FLANGE HAS CORROSION BETWEEN STRINGERS 31S AND 32S. REMOVED RIVETS COMMON TO FRAME AND STRINGER IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW RD 8/4-53-2344. MIN REMAINING THICKNESS NOTED .027", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-5143. ALODINED AND PRIMED WORKED AREAS IAW RD 8/4-53-2344. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED ALUMINIZED TOP COAT IAW RD 8/4-53-5143. APPLIED EXTERNAL TOP COAT IAW SRM 51-25-15-02-01. COMPLIED WITH TC RD 8/4-53-5143.