What was found
X216 FRAME FLANGES AND VERTICAL LEG HAVE CORROSION BETWEEN STRINGERS 28P AND 31P. REMOVED COMMON FASTENERS TO FRAME AND STRINGER CLIP IAW SRM 51-42-05-02-01 AND REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN THICKNESS NOTED .035", CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD 8/4-53-5143. ALODINED, PRIMED AND INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. PAINTED IAW SRM 51-25-15-02-01.