What was found
STRINGER 31P BS -18.25 X1.00 HAS CORROSION. REMOVED RIVETS TO FOM IAW SRM 51-42-05-02-01 AND BLENDED CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .062" REF NDTM 51-00-04-910-801 PT 1. HFEC INSPECTED BLENDS, NO CRACKS DETECTED REF NDTM 51-00-06-910-801 PT 1. MATERIAL LOSS FOUND OUT OF LIMITS IAW SRM 53-00-00-02-17. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-5188. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED ALODINE, PRIMER AND PAINT IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01. COMPLIED WITH TC RD 8/4-53-5188.