What was found
FRAME 49.5 FLANGES AND WEB ARE CORRODED STR 33-28S. REMOVED NECESSARY RIVETS AND REMOVED CORROSION FROM FRAME AND WEB IAW SRM 51-42-05-02-01 AND RD 8/4-53-2344. MIN REMAINING THICKNESS ON FRAME .049" ON WEB .047" REF NDTM 51-00-04-910-801 PT 1. VERIFIED AFFECTED AREAS TO BE CRACK FREE USING HFEC REF NDTM 51-00-06-910-801, PT 1. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-5124 AND 8/4-53-2344. ALODINED, PRIMED AND INSTALLED RIVETS IAW RD 8/4-53-5124. APPLIED EXTERNAL TOP COAT IAW SRM 51-25-15-02-01. COMPLIED WITH TC RD 8/4-53-5124.