What was found
LAVATORY SERVICE DOOR CUTOUT AFT LOWER CORNER CORRODED. REMOVED OUTER/INNER DOUBLERS, LAV DOOR ANDLAV PAN IAW Q400 SRM 51-42-05-02-01. REMOVED UPPER AND LOWER DOUBLER PER Q400 SRM 51-42-05-02-01. CLEANED AREA AND SURROUNDING STRUCTURE, NO FURTHER CORROSION FOUND. ALODINED AND PRIMED SERVICE DOOR CUTOUT AREA IAW Q400 SRM 51-25-10-02-01. INTERNAL DOUBLER FOUND OUT OF LIMITS WITH 100% MATERIAL LOSS IAW Q400 SRM 51-21-00-00-02. LOCATED AND DRILLED NEW INTERNAL DOUBLER P/N 85307789-101 IAW Q400 SRM 51-40-07-02-01. INSTALLED INTERNAL AND EXTERNAL DOUBLERS IAW Q400 SRM 51-42-05-02-01. INSTALLED LAV SERVICE PAN IAW Q400 SRM 51-42-05-02-01. Z CHANNEL AT -18.25 AND STR 25S WAS REMOVED WITH STR 25S TO FOM, Z CHANNEL FOUND TO BE OUT OF LIMITS DUE TO CORROSION IAW Q400 SRM 53-10-33-00-01. MATCH DRILLED NEW Z CHANNEL IAW Q400 SRM 51-40-07-02-01. STRINGER REMOVED IAW Q400 SRM 51-42-05-02-01. INSTALLED 25S IAW Q400 SRM 51-42-05-02-01. PRIMED AND APPLIED TOP COAT IAW Q400 SRM 51-25-10-02-01 AND 51-25-15-02-01. INSTALLED LAV SERVICE DOOR SURROUND PROTECTIVE TAPE PER Q400 AMM 52-44-26-400-801. APPLIED PRIMER, TOP COAT PER Q400 AMM 51-44-26-400-801