What was found
STRINGER 24P HAS AREAS OF MISSING PAINT AND CORRODED RIVETS BETWEEN STA X428.500 AND X664. REMOVED CORRODED RIVETS AND STR CLIPS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN THICKNESS NOTED .072, CONFIRMED CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801, PT 1. NOMINAL THICKNESS OF STR .070". STR FOUND TO BE ABOVE NOMINAL THICKNESS IAW DWG 85360221, SHT 5. ALODINED, PRIMED AND INSTALLED STR CLIPS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. APPLIED TOP COAT AND IAW SRM 51-25-15-02-01 AND AMM 51-25-01-390-801.