What was found
CORROSION FOUND BELOW THE WINDOW FRAME AT STATION X 311.420 ON STRINGER 16S. BLENDED CORROSION IAW SRM 51-21-00-02 NDT INSPECTION FOUND NO DEFECTS. TREATED AREA IAW AMM 51-25-16-370-801. BLENDS WITHIN LIMITS IAW RD 8/4-53-5141.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND BELOW THE WINDOW FRAME AT STATION X 311.420 ON STRINGER 16S. BLENDED CORROSION IAW SRM 51-21-00-02 NDT INSPECTION FOUND NO DEFECTS. TREATED AREA IAW AMM 51-25-16-370-801. BLENDS WITHIN LIMITS IAW RD 8/4-53-5141.