As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND BELOW WINDOW FRAME AT STATION 311.420 ON STRINGER 16P. BLENDED CORROSION IAW SRM 51-21-00-00-02. NDT ANALYSIS SHOWED NO DEFECTS. TREATED AFFECTED AREA IAW AMM 51-25-16-390-801 AND PRIMED. BLENDS FOUND TO BE WITHIN LIMITS IAW RD 8/4-53-5191.