What was found
FRAME 19.4 FLANGES AND WEB ARE CORRODED STR 28P-32P. REMOVED NECESSARY RIVETS FOR ACCESS AND REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801, PT 1. CONFIRMED CRACK FREE IAW NTM 51-00-06-910-801 PT 1 AND NTM 51-00-04-910-801 PT 1. ALODINED AND PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED RIVETS IAW SRM 51-42-05-02-01. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-5140. COMPLIED WITH TC RD 8/4-53-5140.