What was found
FRAME 1.0, FLANGES ARE CORRODED STR 31S-33. REMOVED RIVETS FROM FRAME 1.0 FLANGES BETWEEN STR 31S-33 IAW SRM 51-42-05-02-01, REV 12. REMOVED CORROSION ON FRAME 1.0 FLANGES BETWEEN STR 31S-33 IAW SRM 51-21-00-00-02, REV 12. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801, PART 1, REV 7. MINIMUM THICKNESS OF VERTICAL WEB 31S TO 32S, MEASURED 0.049" AND SKIN FLANGE MINIMUM MEASURED 0.046". MINIMUM THICKNESS 32S-33 ON FLANGE MEASURED 0.044" AND ON VERTICAL WEB MEASURED 0.045". CONFIRMED CRACK FREE REF NTM 51-00-06-910-801 PT 1, REV 7. ALODINED AND PRIMED IAW SRM 51-21-10-02-01, REV 12 AND SRM 51-25-10-02-01, REV 12. NOMINAL THICKNESS OF FRAME X1.0 IS .050". MATERIAL LOSS FOUND TO BE WITHIN LIMITS ON SKIN FLANGE 31S-32S IAW Q400 SRM 53-20-15-00-01, 53-00-00-02-09 REV 12. MATERIAL LOSS FOUND TO BE OUT OF LIMITS ON SKIN FLANGE 32S-33 AND VERTICAL WEB 31S-33 IAW SRM 53-20-15-00-01, REV 12. OK TO INSTALL RIVETS. INSTALLED RIVETS INTO SKIN FLANGES BETWEEN STR 31S TO 32S IAW SRM 53-00-00-02-09, REV 12. INSTALLED RIVETS INTO SKIN FLANGE BETWEEN STR 32S TO 33 IAW SRM 51-42-05-02-01, REV 12. APPLIED ALUMINIZED PAINT TO REWORKED AREA IAW SRM 53-00-00-02-09, 51-25-15-02-01 REV 12. CPC WILL BE COMPLETED ON TC 531000Q01-60176-CMBD, WO 142457. APPLIED EXTERNAL TOPCOAT IAW SRM 51-25-15-02-01, REV 12. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD8/4-53-5139, ISSUE 1. COMPLIED WITH TC RD8/4-53-5139, WO 142457.