What was found
FRAME 1.0, FLANGES ARE CORRODED STR 29P-33. REMOVED RIVETS FROM FRAME 1.0 FLANGES BETWEEN STR 33-29P IAW SRM 51-42-05-02-01, REV 12. REMOVED CORROSION ON FRAME 1.0 FLANGES BETWEEN STR 29P-33 IAW SRM 51-21-00-00-02, REV 12. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801, PART 1, REV 7. MINIMUM THICKNESS 29P-30P MEASURED 0.048" ON VERTICLE WEB AND 0.046" ON SKIN FLANGE, 32P-31P MEASURED 0.047" ON VERTICALE WEB AND 0.044" ON SKIN FLANGE, 32P-33, MEASURED 0.048" ON VERTICAL WEB AND 0.046" ON SKIN FLANGE. CONFIRMED CRACK FREE REF NTM 51-00-06-910-801, PT 1, REV 7. ALODINED AND PRIMED IAW SRM 51-21-10-02-01 REV 12 AND SRM 51-25-10-02-01 REV 12. NOMINAL THICKNESS OF FRAME X1.0 IS .050". MATERIAL LOSS FOUND TO BE WITHIN LIMITS ON SKIN FLANGES 29P-30P AND 32P-33 IAW SRM 53-00-00-02-09, REV 12. MATERIAL LOSS FOUND TO BE OUT OF LIMITS ON SKIN FLANGE 32P-31P AND VERTICAL WEB BETWEEN 29P-33 IAW SRM 53-20-15-00-01, REV 12. OK TO INSTALL RIVETS. INSTALLED RIVETS INTO SKIN FLANGES BETWEEN STR 29P-30P AND STR 32P-33 IAW SRM 53-00-00-02-09, REV 12. INSTALLED RIVETS INTO SKIN FLANGE BETWEEN 30P-31P IAW SRM 51-42-05-02-01, REV 12. APPLIED ALUMINIZED PAINT TO REWORKED AREA IAW SRM 53-00-00-02-09, 51-25-15-02-01 REV 12. CPC WILL BE COMPLETED ON TASK CARD 531000Q01-60176-CMBD, WO 142457. APPLIED EXTERNAL TOP COAT IAW SRM 51-25-15-02-01, REV 12. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD8/4-53-5139 ISSUE 1. NOTE: BETWEEN STRINGERS 30P-31P CORROSION WAS LIMITED TO FASTENERS ONLY. COMPLIED WITH TC RD8/4-53-5139, WO 142457.