What was found
FRAME 19.4 FLANGES AND WEB ARE CORRODED STR 33-29S. REMOVED RIVETS TO FOM, REMOVED CORROSION IAW SRM 51-42-05-02-01 AND SRM 51-21-00-00-02 REV 12. PERFORMED UT THICKNESS OF BLENDS IAW NTM 51-00-04-910-801, PART 1, REV 7. MINIMUM REMAINING THICKNESS 29S-30S MEASURED 0.038", 30S-31S MEASURED 0.040" ON VERTICAL WEB AND 0.039" ON SKIN FLANGE, 31S-32S MEASURED 0.040" ON VERTICAL WEB AND 0.038 ON SKIN FLANGE, 32S-33 MEASURED 0.037 ON VERTICAL WEB AND 0.034" ON SKIN FLANGE. CONFIRMED CRACK FREE REF NM 51-00-06-910-801 PT 1 REV 7. ALODINED AND PRIMED IAW SRM 51-21-10-02-01, REV 12 AND SRM 51-25-10-02-01, REV 12. OK TO INSTALL RIVETS BETWEEN STRG 29S-32S. REINSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. NOTE: ALLOWANCES TO TREAT AND PAINT AND INSTALL RIVETS GIVEN VIA EMAIL IN ADVANCE OF RD FROM MFG REF AGOP-13-1366158. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD8/4-53-5140 ISSUE 2, DATED 7FEB13. APPLIED INTERIOR AND EXTERIOR TOP COAT AND CPC IAW RD8/4-53-5140 ISS 2. COMPLIED WITH TC RD8/4-53-5140, WO 142457.