What was found
FRAME 136, FLANGES AND WEB ARE CORRODED STR 30P-33. REMOVED RIVETS IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. REMOVED STANCHION 31P AT 136 IAW SRM 51-42-05-02-01. REMOVED CROSS BRACE AFT OF FR 136 IAW AMM 20-10-01-430-801. REMOVED CORROSION FROM FRAME AFT OF STANCHION IAW SRM 51-21-00-00-02. VERIFIED MIN THICKNESS OF BLENDS IAW NTM 51-00-04-910-801, PT 1 MIN FLANGE THICKNESS .032". CONFIRMED CRACK FREE REF NTM 51-00-06-910-801 PT 1. ALODINED, PRIMED IAW SRM 51-21-10-02-01 AND 51-25-10-02-01. INSTALLED RIVETS IAW SRM 51-42-05-02-01. APPLIED TOP COAT IAW SRM 51-25-15-02-01. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-5138 AND RD 8/4-53-2344. ALODINE, PRIMED WORKED AREAS AND INSTALLED FASTENERS IAW RD 8/4-53-5138. MATCH DRILLED NEW STANCHION AT 31P STA 136 IAW SRM 51-40-07-02-01. INSTALLED STANCHION IAW SRM 51-42-05-02-01. INSTALLED CROSS BRACE AFT OF FRAME 136 SRM 51-41-05-00-01. PRIMED AND PAINTED RD 8/4-53-5138. CORROSION BLENDED IAW RD 8/4-53-5138. COMPLIED WITH TC RD 8/4-53-5138.