What was found
FRAME 156 FLANGES AND WEB ARE CORRODED STR 29S-33. REMOVED RIVETS FROM FLANGES AND LOWER OTBD PORTION OF STANCHION IAW SRM 51-42-05-02-01. REMOVED CORROSION IAW SRM 51-21-00-00-02. MIN THICKNESS NOTED .037", CONFIRMED CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1. ALODINED, PRIMED AND INSTALLED RIVETS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. PAINTED INT IAW SRM 51-25-15-02-01. APPLIED AV-8 AND EXT SURFACE PROTECTION IAW SRM 51-25-10-02-01, 51-25-15-02-01 AND RD 8/4-53-5160. COMPLIED WITH TC RD 8/4-53-5160.