What was found
AFT ENTRY DOOR BEAM TWO CRACKED AT CENTER LOCATION. CUTOUT DAMAGED AREA IAW RD8/4-52-892. VERIFIED CRACK FREE PER RD8/4-52-892. MATCH DRILLED NEW BEAM IAW SRM 51-40-07-02-01 & 51-20-00-00-01. INSTALLED BEAM IAW SRM 51-42-05-02-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT ENTRY DOOR BEAM TWO CRACKED AT CENTER LOCATION. CUTOUT DAMAGED AREA IAW RD8/4-52-892. VERIFIED CRACK FREE PER RD8/4-52-892. MATCH DRILLED NEW BEAM IAW SRM 51-40-07-02-01 & 51-20-00-00-01. INSTALLED BEAM IAW SRM 51-42-05-02-01.