What was found
BS 236 FRAME, FLANGES AND VERTICAL LEG HAVE CORROSION BETWEEN STR 29S AND 33. REMOVED RIVETS 14EA BETWEEN 29S AND 33 FLANGES TO ACCESS FOR CORROSION REMOVAL IAW SRM REV 12 51-42-05-02-01. REMOVED CORROSION FROM X236 FRAME, FLANGES AND VERTICAL LEGS BETWEEN STRINGER 29S-33 IAW SRM 53-00-00-02-09 AND SRM 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .032" CONFIRMED AFFECTED AREAS CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801 PT 1. ALODINED, PRIMED AND INSTALLED RIVETS ON X236 FRAME FLANGES BETWEEN STR 29S AND 33 IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01. PAINTED INT IAW SRM 51-25-15-02-01. DAMAGE IS WITHIN LIMITS IAW RD8/4-53-5129. OMPLIED WITH HRZ TC RD8/4-53-5129.