What was found
BS 301 FRAME FLANGES AND VERTICAL LEG HAVE CORROSION BETWEEN STR 29P AND 33. REMOVED RIVETS FROM FLANGES BETWEEN STR 29P AND 33 FOR ACCESS IAW SRM 51-42-05-02-01, REV 12. REMOVED CORROSION FROM FRAME FLANGES AND VERTICAL LEFS IAW SRM 51-21-00-00-02, REV 12. MIN THICKNESS NOTED .036", CONFIRMED CRACK FREE REF NTM 51-00-04-910-801 PT 1 & 51-00-06-910-801, PT 1, REV 7. ALODINED IAW IAW SRM 51-21-10-02-01, REV 12. PRIMED IAW SRM 51-25-10-02-01, REV 12. INSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. ALLOWANCE GIVEN TO CONTINUE REPAIR CIA EMAIL IN ADVANCE TO RD FROM MFG- REF DTRA-13-157465. APPLIED PRIMER AND TOP COAT IAW SRM 51-25-10-02-01 + 51-25-15-02-01, REV 12. APPLIED CPC IAW AMM 51-25-01-390-801, REV 40. APPLIED EXTERNAL TOP COAT IAW SRM 51-25-15-02-01, REV 12. MATERIAL LOSS FOUND TO BE IN LIMITS IAW RD8/4-53-5158, ISSUE 1. COMPLIED WITH TC RD8/4-53-5158, WO 142457.