What was found
LT FLAP NR 4 AND NR 5 FLAP TRACK DEAD WEIGHT ROLLERS FAILED GAP CHECK. ADJUSTED LOWER DEAD WEIGHT ROLLERS ON LT NR 4 AND NR 5 FLAP TRACKS IAW AMM 27-52-00-820-802 PARA 1-3 AND 4C STEP (1)-(6) REV 40 DEAD WEIGHT ROLLERS FAILED GAP CHECK. TOOK MEASUREMENTS BETWEEN 0 DEGREES AND 15 DEGREES. ADJUSTED LT NR 5 INBD TO A MIN OF .020 IAW AMM 27-52-00-820-802, PARA 1-3 AND 4C STEP (1)-(6) REV 40 . RIGGED THE LT OTBD FLAP IAW AMM 27-52-00-820-802 PARA 4C STEP (7)-(10) REV 40 AND AMM 27-52-00-830-801, PARA 1-4A, REV 40. IN ACCEPTABLE SERVICE LIMITATIONS IAW CSL 84-27-021, REV 5.