What was found
LEFT NR 3 FLAP TRACK LOWER RAIL GOUGED AT 35 DEGREE POSITION. BLENDED AREA OF CONCERN IAW SRM 51-50-50-02-03 TO A SMOOTH CONTOUR. BLEND AT 35 DEGREE POSITION (24.35"-26.2" FROM FWD EDGE OF LOWER FLAP TRACK) MEASURES 1.85"L X .4"W IS THROUGH THE CARBON/CARBIDE COATING. THERE IS NO DAMAGE FOUND TO THE UNDERLYING METAL. BLEND IS WITHIN LIMITS IAW SRM 57-50-50-02-03. PERFORMED NDT INSPECTION OF THE LT NR 3 LOWER FLAP TRACK REPAIR AREA IAW NDT MANUAL PT 1 51-00-06-910-801 EDDY CURRENT METHOD. NO DEFFECTS NOTED. COMPLETED REPAIR PROCEDURE OF LT NR 3 FLAP TRACK LOWER RAIL AT 35 DEGREE POSITION IAW SRM 57-50-50-02-03.