What was found
CORROSION ON PANEL 524AT MATING SURFACE. REMOVED AND BLENDED CORROSION IAW SRM R12 57-20-02-02 MIN REMAINING THICKNESS .115 WITHIN LIMITS IAW SRM REV 12 57-20-35-02-02. ALODINED, PAINTED AND RE-IDENTIFIED IAW SRM 57-20-35-02-02, REV 12. CONFIRMED CRACK FREE IN AFFECTED AREAS REF NTM 51-00-06-910-801, PT 1, REV 7. PRIOR TO BLENDING OUTER SEAL WAS REMOVED IAW SRM REV 12 57-20-35-02-02. INSTALLLED NEW OUTER SEAL IAW SRM REV 12 57-20-35-02-02.