What was found
CORROSION ON PANEL 524BT MATING SURFACE. REMOVED CORROSION AND BLENDED IAW SRM REV 12 57-20-35-02-02. MIN REMAINING THICKNESS .118 WITHIN LIMITS IAW SRM REV 12 57-20-35-02-02. ALODINED, PAINTED AND RE-IDENTIFIED IAW SRM, REV 12 57-20-35-02-02. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1 REV 7. OUTER SEAL WAS REMOVED PRIOR TO BLENDING IAW SRM 57-20-35-02-02, REV 12. INSTALLED NEW OUTER SEAL IAW SRM REV 12 57-20-35-02-02.