What was found
MAIN CABIN DOOR HARD TO OPEN FROM INSIDE. COMPLIED WITH FUNCTIONAL TEST OF MAIN CABIN DOOR IAW MM TASK 52-11-00-720-802. FOUND BOTH OPEN AND CLOSE LOAD VALUES 15 LBS. OVER LIMITS. ADJUSTED MAIN CABIN DOOR STOP BOLTS AND GUIDES IAW MM TASK 52-11-06-400-801, PARA 4B. MAIN CABIN DOOR FUNCTIONAL TEST NOW GOOD IAW MM TASK 52-11-00-720-802. OPEN AND CLOSE LOAD VALUES WERE GOOD WITH INSIDE AND OUTSIDE HANDLES. RETURNED TO SERVICE.