What was found
FRAME WEB AREA OF FR 236, STR 30P HAS CORROSION. REMOVED CORROSION IAW SRM 51-21-00-00-02, REV 12. VERIFIED AFFECTED TO BE CRACK FREE REF NDTM PART 6, TASK 51-00-01-250-801, REV 8. MINIMUM THICKNESS NOTED, .043 REF NDTM PART 1, TASK 51-00-04-910-801, REV 8. NOMINAL THICKNESS OF FRAME IS .040IN IAW DWG 85361310 AND SRM 53-30-15-00-01, ITEM 4, REV 12. CORROSION BLEND IS IN LIMITS IAW SRM 53-00-00-02-09, REV 12. APPLIED ALODINE PRIMER AND PAINT IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01 REV 12.