What was found
CORROSION ON RT WING LANDING INBD AND OTBD FOR PANEL 624BT. REMOVED CORROSION IAW SRM 57-20-35-02-05, REV 12. MIN THICKNESS NOTED .085", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801, PT 1 AND 51-00-06-910-801 PT 1, REV . FOUND BLENDS TO BE WITHIN LIMITS IAW SRM 57-20-35-02-05, REV 12. APPLIED ALODINE AND PRIMER IAW SRM 51-21-10-02-01 AND 51-25-40-02-01, REV 12.