What was found
FRAME FLANGES AT FR 155 STR 32-30P HAVE CORROSION. REMOVED 1 EA RIVET TO FOM AND REMOVED CORROSION IAW 51-42-05-02-01 AND 53-00-00-02-09, REV 12. REMOVED ADDITIONAL RIVETS TO FOM IAW SRM 51-42-05-02-01, REV 12. VERIFIED AFFECTED AREAS TO BE CRACK FREE NDTM PART 6, TASK 51-00-01-250-801, REV 8 MIN THICKNESS NOTED, .043" REF NDTM PART 1 TASK 51-00-04-910-801, REV 8. NOMINAL THICKNESS IS .040" REF DWG 85328143, FOUND TO BE WITHIN LIMITS IAW SRM 53-20-15-00-01, REV 12. ALODINE AND PRIMER REWORKED AREA IAW SRM 51-21-10-02-01, 51-25-10-02-01 REV 12. INSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. APPLIED TOP COAT SRM 51-25-15-02-01 REV 12. APPLIED CPC IAW AMM 51-25-01-390-801, REV 40.