What was found
FRAME FLANGES AT FR 196 STR 32-30P HAVE CORROSION. REMOVED 10 RIVETS AND REMOVED CORROSION IAW SRM 53-00-00-02-09, REV 12. VERIFIED AFFECTED AREAS TO BE CRACK FREE REF NDTM PART 6, TASK 51-00-01-250-801, REV 8. MINIMUM THICKNESS REMAINING NOTED BETWEEN STRINGER 31P AND 30P .043 ON THE FLANGE AND .044 ON THE WEB AND BETWEEN 32P AND 31P, .042 REF NDTM PART 1 TASK 51-00-04-910-801 REV 8. NOMINAL THICKNESS OF FRAME IS .040 IAW SRM 53-20-15-00-01, ITEM 432, REV 12 AND DWG 85328121. CORROSION REMOVAL IS WITHIN LIMITS OF SRM REPAIR 53-00-00-02-09, REV 12. ALODINED AND PRIMED RIVET HOLES AND INSTALLED REMOVED RIVETS AS REQUIRED IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-42-05-02-01, REV 12. APPLIED ALODINE PRIMER AND TOP COAT TO REPAIR AREAS IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01 REV 12. APPLIED CPC AMM 51-25-01-390-801, REV 40.