What was found
FRAME FLANGES AT FR 196 STR 32-30S HAVE CORROSION. REMOVED 11 RIVETS AND REMOVED CORROSION IAW SRM 53-00-00-02-09, REV 12. VERIFIED AFFECTED AREAS TO BE CRACK FREE REF NDTM PART 6, TASK 51-00-01-250-801, REV 9. MINIMUM THICKNESS REMAINING NOTED BETWEEN STRINGER 31S AND 30S .044 ON THE FLANGE AND .046 ON THE WEB, AND BETWEEN STRINGER 31S AND 32S, .044 ON THE FLANGE AND .047 ON THE WEB REF Q400 NDTM PART 1 TASK 51-00-04-910-801 REV 8. NOMINAL THICKNESS OF FRAME IS .040IN IAW SRM 53-20-15-00-01, ITEM 432, REV 12 AND DWG 85328121. CORROSION REMOVAL IS WITHIN LIMITS IAW SRM 53-00-00-02-09, REV 12. ALODINED AND PRIMED RIVET HOLES AND INSTALLED REMOVED RIVETS AS REQUIRED IAW SRM 51-21-10-02-01, 51-25-02-01 AND 51-42-05-02-01 REV 12. APPLIED ALODINE PRIMER AND TOP COAT IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01 REV 12. APPLIED CPC IAW AMM 51-25-01-390-801, REV 40.