What was found
FRAME FLANGE OF FR 94.8 STR 31S HAS CORROSION. REMOVED 12 RIVETS TO FOM IAW SRM 51-42-05-02-01, REV 12, REMOVED CORROSION IAW SRM 51-21-00-00-02, REV 12. VERIFIED AFFECTED AREAS TO BE CRACK FREE REF NDTM PT 6, TASK 51-00-01-250-801, REV 8. MIN THICKNESS REMAINING NOTED .039 BETWEEN STRINGER 31S AND 30S REF NDTM TASK 51-00-04-910-801, REV 8. ALL WORK PERFORMED IAW SRM 53-00-00-02-09, REV 12. NOMINAL THICKNESS .040" IAW SRM 53-20-15-00-01, REV 12. MATERIAL LOSS IN LIMITS IAW SRM 53-00-00-02-09, REV 12, MIN THICKNESS REMAINING NOTED .041" BETWEEN STRINGERS 30S AND 29S REF NDTM 51-00-04-910-801, PT 1, REV 8. ALODINED AND PRIMED IAW SRM 51-21-10-02-01, 51-25-10-02-01 REV 12. INSTALLED 12 RIVETS IAW SRM 51-42-05-02-01, REV 12. APPLIED TOP COAT AND CPC IAW SRM 51-25-15-02-01, REV 12 AND AMM 51-25-01-390-801, REV 40.