What was found
FRAME FLANGE AT FR 19.4 STR 33-32S HAS CORROSION. REMOVED RIVETS TO FOM REMOVED CORROSION IAW SRM 51-42-05-02-01 AND 51-21-00-00-02, REV 12 MIN THICKNESS NOTED .038", CONFIRMED CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801, PT 1, REV 8. BLENDS WITHIN LIMITS SRM 53-00-00-02-09, REV 12. INSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12. PRIOR TO INSTALLING RIVETS, ALODINE AND PRIMED REWORKED AREA IAW SRM 51-21-10-02-01, 51-25-10-02-01, REV 12. APPLIED INTERIOR AND EXTERIOR TOPCOAT, APPLIED CIC TO REWORKED AREA IAW SRM 53-00-00-02-09, REV 12.