What was found
FRAME FLANGES AT FR 19.4 STR 31-29S HAVE CORROSION. REMOVED RIVETS TO FOM, REMOVED CORROSION IAW SRM 51-42-05-02-01 & 51-21-00-00-02 REV 12. NO CORROSION NOTED BETWEEN 31S-32S. MIN THICKNESS NOTED .036", CONFIRMED CRACK FREE CONDITION REF NTM 51-00-04-910-801 PT 1 & 51-00-06-910-801 PT 1, REV 8. NOMINAL THICKNESS .040, FLANGES IN LIMITS IAW SRM 53-00-00-02-09 TR ALODINED, PRIMED, AND REINSTALLED RIVETS IAW SRM 51-42-05-02-01, REV 12, SRM 51-21-10-02-01 REV 12, AND SRM 51-25-10-02-01, REV 12. PRIMED RIVET TAILS, APPLIED TOP COAT AND CPC IAW SRM 51-25-10-02-01, 51-25-15-02-01, REV 12 AND AMM 51-25-01-390-801, REV 40. APPLIED EXT PRIMER AND TOP COAT IAW SRM 51-25-45-02-01 AND 51-25-15-02-01, REV 12.