What was found
FRAME 32.4, STANCHION AT STR 31P HAS A DENT. REMOVED BOLTS FROM CROSS BRACE TO FOM IAW SRM REV 12 51-41-00-00-01. REMOVED STANCHION FROM FRAME 32.4 AT STR 31P IAW SRM REV 12 51-42-05-02-01. STANTION FOUND TO BE OUT OF LIMITS IAW SRM 53-20-43-00-01, REV 12 MATCH DRILLED NEW STANTION IAW SRM 51-42-05-02-01, REV 12. REINSTALLED STANTION AND BOLTS FROM CROSS BRACE IAW SRM 51-42-05-02-01 & SRM 51-41-05-00-01, REV 12. APPLIED TOP COAT + CPC IAW SRM 51-25-15-02-01, REV 12 AND AMM 51-25-01-390-801, REV 40.