What was found
FRAME FLANGES AT FR 71.2 STR 32-29P HAVE CORROSION. REMOVED RIVETS FOR ACCESS IAW SRM 51-42-05-02-01, REV 12. BLENDED CORROSION IAW SRM 53-00-00-02-09, REV 12. CLEANED BETWEEN STR 30-29P ON FRAME FLANGE 71.2, NO CORROSION NOTED IAW SRM REV 12 51-26-00-02-01. MIN THICKNESS NOTED .044", CONFIRMED CRACK FREE CONDITION REF NTM 51-00-04-910-801 PT1 + 51-00-06-910-801 PT 1 REV 8. BLENDS FOUND TO BE WITHIN LIMITS IAW SRM 51-42-05-02-01, REV 12. PRIOR TO INSTALLING RIVETS APPLIED ALODINE AND PRIMER IAW SRM 53-00-00-02-09, REV 12. APPLIED CPC IAW SRM 53-00-00-02-09, REV 12. PRIOR TO APPLYING CPC TOPCOAT APPLIED IAW SRM 53-00-00-02-09, REV 12.