What was found
FRAME FLANGES AT FR 71.2 STR 33-28S HAVE CORROSION. REMOVED RIVETS FOR ACCESS FROM FR 71.2 STR 33-28S IAW SRM REV 12 51-42-05-02-01. BLENDED CORROSION IAW SRM REV 12 53-00-00-02-09. CLEANED BETWEEN STR 30-29S ON FRAME 71.2 IAW SRM REV 12 51-26-00-02-01, NO CORROSION NOTED. MIN THICKNESS NOTED .037", CONFIRMED CRACK FREE CONDITION REF NTM 51-00-04-910-801 PT1 + 51-00-06-910-801 PT 1 REV 8. BLEND FOUND TO BE WITHIN LIMITS IAW SRM 53-00-00-02-09, REV 12. INSTALLED RIVETS FR 71.2, STR 33-28S IAW SRM 51-42-05-02-01, REV 12. PRIOR TO INSTALLING RIVETS APPLIED ALODINE AND PRIMER IAW SRM 53-00-00-02-09, REV 12. APPLIED CPC IAW SRM 53-00-00-02-09, REV 12. PRIOR TO APPLYING CPC TOPCOAT APPLIED IAW SRM 53-00-00-02-09, REV 12.