What was found
FRAME FLANGES AT FR 116 STR 33-29S HAVE CORROSION. REMOVED 22 RIVETS AND CORROSION FROM FRAME 116 FLANGES STR 33-29S IAW SRM REV 12 53-00-00-02-09. MIN THICKNESS NOTED .026", CONFIRMED CRACK FREE CONDITION REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801, PT 1 REV 8. FLANGES 33-32S MEASURED .045, 31-30S MEASURED .043, 30-29S MEASURED .046 WITHIN LIMITS IAW SRM 53-00-00-02-09, REV 12, FLANGE 32-31S MEASURED .026 OUT OF LIMITS IAW SRM 53-00-00-02-09 REV 12. OK TO TREAT PRIME AND INSTALL RIVETS BETWEEN STGRS 33-32S AND 31S-29S AND TO DO FLANGE REPAIR IAW 53-00-00-02-18, 32S-31S. REMOVED DAMAGED FLANGE IAW SRM 53-00-00-02-18, REV 12, STEP 7B(3)-(4), FABRICATED REPAIR FLANGE USING 2024T3 .050" PO90512F IAW SRM 53-00-00-02-18, REV 12 STEPS 8A(1)-(9). VERIFIED TRIM FRAME EDGE CRACK FREE IAW NTM 51-00-06-910-801 PART 1 REV 8. OK TO INSTALL REPAIR ANGLE. INSTALLED REPAIR ANGLE AND RIVETS IN FRAME FLANGES FROM BS116 STR 33 TO 29S IAW SRM 51-42-05-02-01, REV 12 AND SRM 53-00-00-02-18, REV 12. PRIOR TO INSTALLAITON OF REPAIR ANGLE AND REMOVED RIVETS, APPLIED ALODINE AND PRIMER TO ALL REQUIRED AREAS IAW SRM 51-21-10-02-01 AND 51-25-10-02-01, REV 12. APPLIED TOP COAT TO INTERIOR AND EXTERIOR IAW SRM 51-25-15-02-01 REV 12. APPLIED CPC IAW AMM 51-25-01-390-801, REV 40.