What was found
FRAME FLANGES AT FR 258.5 STR 32-30S HAVE CORROSION. REMOVED FASTENERS AT FRAME X258.5 FROM STRINGER 30S-32S IAW SRM REV 12 51-42-05-02-01. REMOVED CORROSION FROM X258.5 FRAME FLANGES AT STRINGER 30S-32S IAW SRM REV 12 53-00-00-02-09. MIN THICKNESS NOTED .028", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1, REV 8. FLANGE BETWEEN STR 31-30S MEASURED .042 WITHIN LIMITS IAW SRM 53-00-00-02-09 REV 12. FLANGE BETWEEN 32-31S OUT OF LIMITS IAW SRM 53-00-00-02-09, REV 12. OK TO TREAT PRIME AND INSTALL RIVETS BETWEEN 31S-30S AND DO FLANGE REPAIR IAW 53-00-00-02-18 32S-31S. ALODINED AND PRIMED IAW SRM 53-00-00-02-09, REV 12. REMOVED 32-31S FLANGE IAW SRM 53-00-00-02-18. CONFIRMED FLANGE CUTOUT CRACK FREE REF NDTM 51-00-06-910-801 PT 6, REV 7. FABRICATED ANGLE FOR LOOSE ANGLE REPAIR WITH 2024-T3 .050 PO 90512F IAW SRM 53-00-00-02-18 REV 12. LOCATED, DRILLED, ALODINED AND PRIMED IAW SRM 53-00-00-02-18, REV 12. OK TO INSTALL REPAIR ANGLE. INSTALLED REPAIR ANGLE IAW SRM REV 12 53-00-00-02-18. INSTALLED REMAINING FASTENERS IN WORKED FRAME FLANGES FROM STR 32-30S IAW SRM 51-42-05-02-01, REV 12. APPLIED PRIMER AND PAINT TO INTERIOR IAW SRM 51-25-10-02-01 AND 51-25-15-02-01, REV 12. APPLIED CPC IAW AMM 51-25-01-390-801, REV 40. ALODINED PRIMED AND PAINTED EXTERIOR IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01, REV 12.