What was found
FRAME FLANGES AT FR 258.5 STR 33-30P HAVE CORROSION. REMOVED FASTENERS AT FRAME 258.5 FROM STRINGER 30P-33 IAW SRM REV 12 51-42-05-02-01. REMOVED CORROSION FROM SKIN FLANGES AT FRAME 258.5 FROM STRINGER 30P-33 IAW SRM REV 12 53-00-00-02-09. MIN THICKNESS NOTED .035", CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-04-910-801 PT 1 AND 51-00-06-910-801 PT 1 REV 8. FLANGE BETWEEN 31-32P MEASURED .036, 32P-33 MEASURED .046, FLANGES 33-31P WITHIN LIMITS IAW SRM 53-00-00-02-09, REV 12, FLANGE 31-30P OUT OF LIMITS IAW SRM 53-00-00-02-09 REV 12. OK TO TREAT, PRIME AND INSTALL RIVETS 31P-33 AND DO FLANGE REPAIR IAW SRM 53-00-00-02-18 31P-30P. ALODINED AND PRIMED IAW SRM 53-00-00-02-09, REV 12. REMOVED 31-30P FLANGE IAW SRM 53-00-00-02-18, REV 12. CONFIRMED FLANGE CUTOUT CRACK FREE REF NDTM 51-00-06-910-801 PART 6, REV 7. FABRICATED ANGLE FOR LOOSE ANGLE REPAIR WITH 2024-T3 .050 PO 9051F IAW SRM 53-00-00-02-18, REV 12. LOCATED DRILLED ALODINED AND PRIMED ANGLE IAW SRM 53-00-00-02-18 REV 12. OK TO INSTALL REPAIR ANGLE. INSTALLED REPAIR ANGLE IAW SRM REV 12 53-00-00-02-18. INSTALLED REMAINING FASTENERS IN WORKED FRAME FLANGES FROM STR 30P-33 IAW SRM 51-42-05-02-01, REV 12. PRIMED AND PAINTED INTERIOR IAW SRM 51-25-10-02-01 AND 51-25-15-02-01, REV 12. APPLIED CPC IAW AMM 51-25-01-390-801, REV 40. ALODINED PRIMED AND PAINTED EXTERIOR IAW SRM 51-21-10-02-01, 51-25-10-02-01 AND 51-25-15-02-01, REV 12.